Unimedsume Trading Co., Ltd

Home> Industry Information> laboratory equipment principle of vacuum pump

laboratory equipment principle of vacuum pump

September 23, 2019

According to the scope of use and pumping efficiency can be divided into three types of vacuum pumps:

(1) The general pump, the pressure can reach 1.333 ~ 100kPa (10 ~ 760mmHg) for the "rough" vacuum.

(2) oil pump, pressure up to 0.133 ~ 133.3 Pa (0.001 ~ 1mmHg) for the "second highest" vacuum.

(3) Diffusion pump with pressure up to 0.133 Pa and (10-3 mmHg) "high" vacuum.

Pumps and pumps are commonly used in organic chemistry laboratories for both pump and pump. Pumps can be used if low pressure is not required. If the pump is well constructed and pressurized, the pumping efficiency can reach 1067 ~ 3333 Pa ( 8 ~ 25mmHg). The lowest pressure the pump can draw is theoretically equivalent to the water vapor pressure at the time of the water temperature. For example, the water vapor pressure is 3192, 2394, 1197 Pa (8-25 mmHg) when the water temperature is 25 ° C, 20 ° C and 10 ° C, respectively. Pumping with water pump, safety pump should be installed in front of the pump to prevent the pressure drop, the water flow suction; stop pumping before, you should deflate, and then turn off the pump.

To lower the pressure, it is necessary to use the pump, a good pump can be pumped 133.3Pa (1mmHg) below. The quality of the pump depends on its mechanical structure and the quality of the oil, which must be protected when using the pump. If the distillation of volatile organic solvents, the organic solvent will be the result of oil absorption increased vapor pressure, thereby reducing the pumping efficiency, if it is acid gas, it will corrode the pump, if it is steam will make the oil into milk Turbidity and vacuum pump. Therefore, when using the pump must pay attention to the following points:

Between the distillation system and the pump, an absorption device must be installed.

Before distillation, the steam of the organic solvent in the system must be thoroughly drained by a water pump.

If you can pump the air, then try to use the pump, such as distillation of volatile substances can be reduced by pumping first pump, and then switch to the pump.

Decompression system must be kept airtight, all the rubber plug size and hole to be appropriate, rubber hose to use vacuum hose. Wear glass coated with vacuum grease.


The above is the laboratory equipment principle of vacuum pump we have listed for you. You can submit the following form to obtain more industry information we provide for you.

You can visit our website or contact us, and we will provide the latest consultation and solutions

Share to:

Send Inquiry

Home> Industry Information> laboratory equipment principle of vacuum pump

Send Inquiry

Frank

Mr. Frank

Email:

Send Inquiry

Tel:0086-0531-86077860

Fax:

Mobile Phone:+8615666779750Contact me with Whatsapp

Email:

Address:No. 1 Zijinshan Road, Jinan City, China

Mobile Site

Home

Product

Whatsapp

About Us

Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send