Wavelength Range: 190-900nm
Baseline Stability: ≤0.004A/30min
Wavelength Accuracy: ±0.25nm
Packaging: Export Package
Transportation: Ocean,Land,Air
Place of Origin: China
Port: Jinan,Qingdao,Shanghai
Payment Type: L/C,T/T,D/P,Paypal,Money Gram,Western Union
Incoterm: FOB,CFR,CIF,EXW,FCA,CPT,CIP
UFX-210 Atomic Absorption spectrophotometer(AAS)
FEATURES:
Innovated Rich oxygen air-acetylene flame analysis technique
The patented flame analysis technique adopting rich oxygen air-acetylene flame as the substitution for nitrous oxide-acetylene flame for high temperature element analyses, such as Ca, Al, Ba, W, Mo, Ti, V, etc. Flame temperature is continuously adjustable between 2300-2950℃, which makes it possible to choose the best atomization temperature for different elements. It features easy operation, low analysis cost and wide flame AAS analytical range. Rich oxygen flame is will not pollute the environment and is not harmful to human bodies. It’s a break-through in flame AAS analysis.
Integrated flame/graphite furnace atomization system, changeable with flame emission burner
Accurate fully automated control system
Reliable fully automatic graphite furnace analysis
Perfect safety protection measures
Advanced and reliable electronic design
Easy and practical analysis software
Comparison
Characteristic Mass of Some Elements using rich oxygen air-C2H2 flame and other flame methods
Unit: ug/ml
Element | Wavelength (nm) | Rich oxygen air-C2H2 flame | N2O-C2H2 flame | Air-C2H2 flame |
Ca | 422.7 | 0.009 | 0.05 | 0.07 |
Yb | 378.8 | 0.037 | 0.08 | 7.6 |
Eu | 459.4 | 0.137 | 0.3 | 3.0 |
Al | 309.3 | 0.4 | 0.7 | |
Sr | 460.7 | 0.016 | 0.1 | 0.15 |
Ba | 553.5 | 0.1 | 0.4 | 10.0 |
Mo | 313.3 | 0.15 | 0.4 | 0.8 |
W | 255.1 | 3.2 | 5.0 | |
Ga | 287.4 | 0.4 | 1.0 | 1.3 |
Sm | 429.7 | 2.92 | 8.5 | |
La | 550.1 | 37.2 | 35.0 | |
Sn | 224.6 | 0.8 | 3.0 | 50 |
SPECIFICATIONS:
Main Specification | Wavelength range | 190-900nm |
Wavelength accuracy | Better than ±0.25nm | |
Resolution | Two spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%. | |
Baseline stability | 0.004A/30min | |
Background correction | The D2 lamp background correction capability at 1A is better than 30 times. The S-H background correction capability at 1.8A is better than 30 times. | |
Light Source System | Lamp turret | Motorized 6-lamp turret (Two high performance HCLs can be mounted on the turret to increase the sensitivity in flame analysis.) |
Lamp current adjustment | Wide pulse current: 0~25mA, Narrow pulse current: 0~10mA. | |
Lamp power supply mode | 400Hz square wave pulse; 100Hz narrow square wave pulse + 400Hz wide square pulse wave. | |
Optical System | Monochomator | Single beam, Czerny-Turner design grating monochromator |
Grating | 1800 l/mm | |
Focal length | 277mm | |
Blazed Wavelength | 250nm | |
Spectral Bandwidth | 0.1nm, 0.2nm, 0.4nm, 1.2nm, auto switch over | |
Flame Atomizer | Burner | 10cm single slot all-titanium burner |
Spray chamber | Corrosion resistant all-plastic spray chamber. | |
Nebulizer | High efficiency glass nebulizer with metal sleeve, sucking up rate: 6-7mL/min | |
Emission burner provided | ||
Graphite Furnace | Temperature range | Room temperature~3000ºC |
Heating rate | 2000℃/s | |
Graphite tube dimensions | 28mm (L) x 8mm (OD) | |
Characteristic mass | Cd≤0.8 ×10-12g, Cu≤5 ×10-12g, Mo≤1×10-11g | |
Precision | Cd≤3%, Cu≤3%, Mo≤4% | |
Detection and Data Processing System | Detector | R928 photomultiplier with high sensitivity and wide spectral range. |
Software | Under Windows operating system | |
Analytical method | Working curve auto-fitting; standard addition method; automatic sensitivity correction; automatic calculation of concentration and content. | |
Repeat times | 1~99 times, automatic calculation of mean value, standard deviation and relative standard deviation. | |
Multi-task Functions | Sequential determination of multi-elements in the same sample. | |
Condition reading | With model function | |
Result printing | Measurement data and final analytical report printout, editing with Excel. | |
Standard RS-232 serial port communication | ||
Graphite Furnace Autosampler | Sample tray capacity | 55 sample vessels and 5 reagent vessels |
Vessel material | Polypropylene | |
Vessel volume | 3ml for sample vessel, 20ml for reagent vessel | |
Minimum sampling volume | 1μl | |
Repeatable sampling times | 1~99 times | |
Sampling system | Accurate dual pump system, with 100μl and 1ml injectors. | |
Characteristic Concentration and Detection Limit | Air-C2H2 flame Rich oxygen Air-C2H2 flame | Cu: Characteristic concentration ≤ 0.025 mg/L, Detection limit≤0.006mg/L; Ba: Characteristic concentration ≤ 0.22mg/L Al: Characteristic concentration ≤ 0.4mg/L |
Function Expansion | Hydride vapor generator can be connected for hydride analysis. | |
Dimensions and Weight | Main unit | 107×49×58cm, 140kg |
Graphite furnace | 42×42×46cm, 65kg | |
Autosampler | 40×29×29cm, 15kg |
Product Categories : Laboratory Equipment > Spectrophotometer
Home > Products > Laboratory Equipment > Spectrophotometer > UFX-210 Atomic Absorption Spectrophotometer(AAS)
Send Inquiry
Mr. Frank
Email:
Send Inquiry Tel:0086-0531-86077860
Fax:
Mobile Phone:+8615666779750
Email:
Address:No. 1 Zijinshan Road, Jinan City, China
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.